Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Asian Spine Journal ; : 827-830, 2014.
Article in English | WPRIM | ID: wpr-152136

ABSTRACT

We report a very rare case of negative pressure pulmonary edema (NPPE) that occurred immediately after anterior cervical discectomy and fusion (ACDF). The patient was a 25-year-old man who sustained a facet fracture-dislocation of C5 during a traffic accident. After ACDF, he developed NPPE and needed mechanical ventilation. Fortunately, he recovered fully within 24 hours. NPPE is a rare postoperative complication that may occur after cervical spine surgery. The aims of this report are to present information regarding the diagnosis and emergent treatment of NPPE, and to review the previous literature regarding this serious complication.


Subject(s)
Adult , Humans , Accidents, Traffic , Diagnosis , Diskectomy , Postoperative Complications , Pulmonary Edema , Respiration, Artificial , Spine
2.
Asian Spine Journal ; : 267-272, 2013.
Article in English | WPRIM | ID: wpr-98631

ABSTRACT

STUDY DESIGN: Prospective study. PURPOSE: The main purpose of this study was to clarify the range of magnification errors on digital plain radiographs and to determine if there is a correlation between the body mass index (BMI) of a patient and the magnification error. OVERVIEW OF LITERATURE: Most clinicians currently use digital plain radiography. This new method allows one to access images and measure lengths and angles more easily than with the past technologies. In addition, conventional plain radiography has magnification errors. Although few articles mention magnification errors in regards to digital radiographs, they are known to have the same errors. METHODS: We used plain digital radiography and magnetic resonance imaging (MRI) to acquire images of the cervical spine with the goal of evaluating magnification errors by measuring the anteroposterior vertebral body lengths of C2 and C5. The magnification error (ME) was then calculated: ME=(length on radiograph-length on MRI)/length on MRI x100 (%). The correlation coefficient between the magnification error and BMI was obtained using Pearson's correlation analysis. RESULTS: Average magnification errors in C2 and C5 were approximately 18.5%+/-5.4% (range, 0%-30%) and 20.7%+/-6.3% (range, 1%-32%). There was no positive correlation between BMI and the magnification error. CONCLUSIONS: There were magnification errors on the digital plain radiographs, and they were different in each case. Maximum magnification error differences were 30% (C2) and 31% (C5). Based on these finding, clinicians must pay attention to magnification errors when measuring lengths using digital plain radiography.


Subject(s)
Humans , Body Mass Index , Magnetic Resonance Imaging , Prospective Studies , Radiographic Image Enhancement , Radiography , Spine
SELECTION OF CITATIONS
SEARCH DETAIL